Definition
The weld is not correctly made due to the use of an incorrect cable
or shunt.
Description
Cross Sectional Area:
- Too small: Current flow is restricted due to the increase in impedance.
- Too large: Conductor stiffness can cause problems in properly locating
equipment; premature wear to the machine components; or achieving
weld force.
Conductor Length:
- Too long: Current flow is restricted due to the increase in impedance;
proper weld placement can be hindered by cable drag and entanglement;
short circuits may result from the above conditions.
- Too short: Inadequate length can cause problems in properly locating
equipment; premature wear to machine components; or achieving required
weld force.
Detection
Detection evidence may include:
Significance
Quality, Workplace Issues, Cost, Downtime, Maintenance, Throughput (cycle
time; PPH), are all potentially affected by this condition. Special
considerations are noted below:
Quality: Cables that are improperly sized can
cause variations in welds from operator to operator in manual operations.
Subordinate Causes
- Correct conductor not immediately available.
- Increase in jobs per hour, weld current, or weld time requirements.
WeldHelp: To Issue/Cause
Matrix